Celotex Energy-Lok EL3000

Provides a quick and easy method of achieving effective thermal insulation in flat roofing structures. With coated glass tissue facings, EL3000 is manufactured from rigid polyisocyanurate (PIR) using a blend of blowing agents that have zero ozone depletion potential (zero ODP) and a low global warming impact.

Advantages

With Celotex EL3000, you are specifying insulation board that:

Is designed for use in a variety of flat roof systems
Achieves U-values with minimum thickness
Is strong and durable
Is rot proof
Is dimensionally stable and unaffected by temperature cycles
Is easy to cut and shape
Requires minimum number of fixings
Comes in a range of thicknesses from 50-150mm
Is available in two different sizes: 1200mm x 600mm and 1200mm x 2400mm
Note: EL3050 available in 600mm length only

Applications

The facers are suitable for bonding in the following flat roofing applications:

Perforated facer

• Mastic asphalt

• Bituminous built-up roofing systems

Unperforated facer

• Single-ply, fully adhered flat roof systems
• Single-ply, mechanically fixed flat roof systems
• Self-adhesive membranes
• Liquid-applied membranes

Specification

Celotex EL3000 thick comprises polyisocyanurate rigid foam insulation core with glass tissue facings on both sides.

EL3000 is CFC/HCFC free with zero ODP and low GWP.
CE marking compliance to BS EN 13165:2001 and manufactured in accordance with quality management systems BS EN ISO 9001:2000 by Celotex Limited.

All products must be installed in accordance with instructions issued by Celotex Limited.

Physical Properties

 

Method

EL3000

Compressive strength

BS EN 826

≥150kPa

Dimensional stability

BS EN 1604

DS(TH)8

Water vapour resistance

BS EN 12086 Method B

>20MNs/g

Thermal conductivity

BS EN 12667

0.027W/mK <75mm
0.026W/mK 80mm - 110mm
0.025W/mK >120mm

External fire exposure roof test

BS 476-3

Ext. FAB

Reaction to fire

BS EN 13501-1

Euroclass F

 

Celotex TD3000 Technical Data

Product Code

Thickness (mm)

R-value (m2K/W)

Weight (kg/m2)

EL3050

50

1.85

2.10

EL3080

80

3.05

3.06

EL3090

90

3.45

3.38

EL3100

100

3.80

3.70

EL3110

110

4.20

4.02

EL3120

120

4.80

4.34

EL3140

140

5.60

4.98

EL3150

150

6.00

5.30

 

Installation Guidelines

Built-up flat roofing applications

Use Celotex EL3000 high performance insulation in built-up roofing applications, including hot-applied bituminous and mastic asphalt waterproofing systems. The perforated facer is suitable for bonding in mastic asphalt applications and hot bituminous built-up roofing systems.

When designing a flat roof using Celotex EL3000 boards, three basic principles apply:

1. Design to a fall of 1:80, 1:60 or 1:40 as appropriate to the weathering system, type of deck and construction tolerances.
2. Have due regard for the use and design of the building and the need to ensure that the design will not allow a build up of moisture below the waterproofing membrane.
3. Provide adequate protection for both insulation and waterproofing if significant foot traffic is expected either during or after the completion of the roof.

Single-ply membrane flat roofing applications

Use Celotex EL3000 high performance insulation in either mechanically fixed or fully adhered single-ply flat roofing applications. The unperforated facer is suitable for single-ply fully adhered roof systems, self adhesive membranes and liquid-applied membranes.

Alternatively, use Celotex TA3000 high performance insulation in mechanically fixed, single-ply flat roofing systems where the higher compressive strength of the board gives improved resistance to site traffic during installation.

When designing a flat roof using Celotex EL3000 or TA3000 boards, three basic principles apply:

1. Design to a fall of 1:80, 1:60 or 1:40 as appropriate to the weathering system, type of deck and construction tolerances.
2. Have due regard for the use and design of the building and the need to ensure that the design will not allow a build up of moisture below the waterproofing membrane.
3. Provide adequate protection for both insulation and waterproofing if significant foot traffic is expected either during or after the completion of the roof.

Manufacturer's details

Celotex Limited, Lady Lane Industrial Estate, Hadleigh, Ipswich, Suffolk, IP7 6BA

Web site: Celotex Home Page

Web site: Celotex U-value Calclator

Celotex Technical Advisory Service

While just-insulation provides the very best products at the very best prices ...
For the very best advise we recommend you contact the Celotex Technical Advisory Service.
Tel: 0901 996 0100 (30p per minute) Fax: 01473 820 889 Email: technical@celotex.co.uk

Page last updated January 5, 2010
>
 

Order via Internet by 10am for next working day delivery

Telephone orders will require two working days delivery

View the list of all items

sold through our eShop

Celotex Energy-Lok™ EL3000

Ideal for built-up flat roofing applications

» View complete list

Product Categories ...

Bubble Foil Insulation

Insulation Polystyrene

Drywall Partitioning

Acoustic Insulation

Tapes and Cladding

Elastomeric Insulation

Fire Protection

Insulation by Brand ...

Jablite / Jabfloor

Speedline

Site Information ...

 

Celotex EL3000 for effective thermal insulation in flat roofing structures

Energy-Lok™ EL3000

Purpose designed for use in built-up flat roofing applications, including hot-applied bituminous and mastic asphalt water-proofing systems and fully adhered single ply membranes.

Features a coated glass tissue facer, perforated on one side whilst the reverse unperforated facer is suitable for fully adhered single-ply applications.

» Buy Celotex EL3000
Product Datasheet
Installation Guides
Product Certification