Celotex Extra-R XR3000

Manufactured using the latest state-of-the-art restrained rise production line and features the unique Celotex jointless laydown technology.

This technology enables Celotex to offer boards with no visible seams in the foam laydown. This product is targeted at cut-to-fit applications for installation between rafters or joists and will enable users to achieve lower u-values with a single layer of insulation than has been previously possible.

These boards are available from Just-Insulation in thicknesses ranging from 110 to 150 mm with a standard board size of 1200 x 2400 mm. We only sell them ex-stock in full packs.

Technical Specification

Description

Please see the Celotex Tuff-R GA3000 page for details of the technical specifications of this thicker version of that product.

Where Celotex Extra-R XR3000 should be used

This thicker version can be used in any rafter or joist application where there is the need to achieve improved u-Values from those available from a thinner board.

Celotex Extra-R XR3000 between rafters Insulation between rafters Celotex XR3000 between rafters

Use Celotex Extra-R XR3000 high performance thermal insulation in pitched roofs either between and under rafter or between the rafter applications to minimise insulation thickness and give the following benefits ...

Ideal for use where headroom is limited
Provides reliable long term energy savings for buildings
Low emissivity foil facers give improved thermal insulation with cavity air spaces
Creates a warm habitable roof space
No need to insulate water pipes and tanks
Suitable for new build and major refurbishment projects
Minimised additional loading to the structure
Ideal for loft conversions/room in roof applications

The void created by a pitched roof can be made habitable by insulating along the plane of the roof pitch with Celotex rigid PIR insulation boards. This creates a warm, potentially habitable roof space in which water pipes and tanks no longer need to be insulated.

If BS 747: 2000 slater's felt is being used, a minimum 50 mm ventilated air space must be provided between the felt and the cold side of the insulation in order to minimise the risk of condensation formation. This construction is known as a ventilated construction.

With some breathable membranes, the cold side of the insulation may be placed in direct contact with the membrane (check with membrane supplier prior to specification). However, the outer side of the membrane must be adjacent to an air space to allow moisture vapour to escape to the outside of the building. This is known as an unventilated construction.

Insulation for timber frame wall liningTimber frame wall lining with Celotex Rxtra-R

Celotex Insulation for timber frame wall lining Celotex utilises the low lambda values of Celotex tuff R GA3000 and ExtraR XR3000 between the studs, followed by an internal lining of Celotex T-Break TB3000 over the studs, providing for a thin build-up with the excellent thermal insulation.

Benefits:

Offers the thinnest solution available
Provides reliable long term energy savings for buildings
Low emissivity foil facers give improved thermal insulation with cavity air spaces
Provides a vapour control layer when board joints are taped
Reduces thermal bridging through studs and rails
Can be nailed direct to stud framing
Dryline directly over insulation
Provides cavity for services Installation guidelines
Make sure all studs and rails are flush, with no projections, and that services are correctly installed.
Cut Celotex Extra-R XR3000 to fit tightly between all studs and rails.
For optimum thermal performance, the unprinted foil surface should face the air cavity.
Insert insulation into framing and push back to plywood sheathing. Fit services in to cavity if required.
Measure the wall height from floor level to underside of ceiling joists and cut board length to suit, using a trimming knife.
Ensure that the wall insulation is continuous with the floor perimeter insulation.
Cut boards for infill panels, using off-cuts where possible, making sure there are no gaps at wall abutments.
Tightly butt edges of boards together, making sure there are no gaps.
Temporarily secure the boards with clout nails at 600 mm centres. Mark stud lines on board surface as fixing guides for dry lining.
Always fix back to solid timber, both at stud lines and at top and bottom rails.

Ensure that all board surfaces are clean and free from dust and then apply aluminum foil vapour-seal tape to all joints. Taping the joints of the Celotex insulation with self adhesive aluminum foil tape provides a good vapour control layer and improves air tightness.

Seal the insulation at all abutments and service penetrations with a vapour resistant sealant. ? Fix plasterboard lining over the Celotex insulation using plasterboard nails or screws of appropriate length and joint or skim to the desired finish.

No separate vapour check membrane is required in this application; Celotex insulation acts as an effective internal vapour control layer when all joints are sealed. Suspended timber floor insulation Celotex

Suspended timber floor insulation

Fixing floppy quilt insulation between floor joists can be difficult. Insulating a suspended timber floor is made easy using Celotex Insulation cut to fit between joists.

The specification of insulation for ground floors is more complex than that for walls or roofs. This is because the mechanisms for heat flow are affected by the ratio of surface area to perimeter.

With a suspended timber floor, there is little choice but to install the insulation between the joists, but the thermal bridges created by the joists have to be considered.

Continuity of the insulation must be ensured by packing the spaces between the external walls and the joists with insulation. The void below an insulated suspended timber floor must be well ventilated. The insulation must be cut to fit tightly between the joists to prevent heat loss.

Manufacturer's details

Celotex Limited, Lady Lane Industrial Estate, Hadleigh, Ipswich, Suffolk, IP7 6BA

Web site: Celotex Home Page

Web site: Celotex U-value Calclator

Celotex Technical Advisory Service

While just-insulation provides the very best products at the very best prices ...
For the very best advise we recommend you contact the Celotex Technical Advisory Service.
Tel: 0901 996 0100 (30p per minute) Fax: 01473 820 889 Email: technical@celotex.co.uk

Page last updated January 5, 2010
 

Order via Internet by 10am for next working day delivery

Telephone orders will require two working days delivery

View the list of all items

sold through our eShop

Celotex Extra-R XR3000, the general purpose insulation board for floors, walls and roofs

» View complete list

Product Categories ...

Bubble Foil Insulation

Insulation Polystyrene

Drywall Partitioning

Acoustic Insulation

Tapes and Cladding

Elastomeric Insulation

Fire Protection

Insulation by Brand ...

Jablite / Jabfloor

Speedline

Site Information ...

 

Celotex TB3000 is a multi-purpose insulation board developed to provide simple solutions for overcoming localised thermal bridges.

Celotex Extra-R XR3000

Celotex XR3000 is specifically designed for "cut-to-fit" applications between rafters or joists, enabling the achievement of lower U-values with a single layer of insulation than has previously been possible.

XR3000 is entirely appropriate for use in roofs, ceilings, walls, and floors.

» Buy Celotex Xtra-R GA3000
Product Datasheet
Installation Guides
Product Certification
Select product from menu list - - -