YBS Foil-Tec double-sided aluminium foil Insulation for suspended timber floors. High performance material creates a low emissivity air space below the floor, encouraging heat to rise. BRE certified

Foil-Tec Foil Laminate for Insulating Floors

BBA Certified Foil-Tec Single is a multi- layer foil laminate, coated with nitrocellulose to provide a corrosion resistant insulation system.

Foil-Tec Double is a high-performance material which acts creating a low emissivity air space below the floor, thus reflecting the heat back.

Buy Foiltec Single Foil

Buy YBS Foil Products

View related information -

Airtec aluminium multi-layer air bubble film single foil and double foil bubble

Currently your cart has items totaling ... including VAT & Delivery

Aluminium Foil Insulation for Suspended and Concrete Floor Applications - BBA Certificate No. 09/4640

Foil-Tec Single is a multi-layer foil laminate, coated with polyethylene to provide a corrosion resistant insulation system.Foil-tec Single when used with concrete floors is rolled to 25mm x 38mm horizontal counter battens, thus creating the required air gap.

Foil-Tec Single is a high-performance material that works by creating a low emissivity air space below the floor, thus reflecting the heat back.

Foil-Tec Single can be applied to enhance ‘U’ values in new build or refurbished building projects to meet and exceed current Building Regulations

Concrete Floor Applications

Foil-Tec Single is rolled out onto concrete floor with shiny side facing upwards - leaving enough edge overlap for 75mm lip to be left behind skirting.

Timber battens/joists (min 50mm x 50mm) are then laid on top of the Foil-Tec Single, spaced at centres to suit the particular flooring.

The decking is then fixed with screws (at 200mm centres) into battens/joists providing 25mm penetration into the 50mm wide battens/joists

Installation in suspended floor applications

Foil-Tec Single is rolled out with the shiny side Foiltec is seals the floor and wall upstands to provide effective insulation.facing upwards, over the joists

Foil-Tec Single is then nailed in place through the Foil-Tec Saddle Clips to maintain required air gap - 4- per m²

The horizontal joints are overlapped by 100mm and are left open to allow any moisture accumulation to dissipate

Foil-Tec Single must be brought up (behind the skirting board) to 75mm
The decking is then fixed with screws (at 200mm centres) 37mm into the joists

Joist End Fitting Recommendations

Make 2 x 75-100mm cuts in Foil-tec - same width as joist. Then make one further cut, same width again, on each side. Fold up flap(A), fold back flaps (B) and pull Foil-tec (C) up to meet wall. Fix to wall and fit skirting board over, concealing Foil-tec.


Installation for concrete floor applications

Foil-Tec Single is rolled out onto concrete floor with shiny side facing upwards - leaving enough edge overlap for 75mm lip to be left behind skirting

Timber battens/joists (min 50mm x 50mm) are then laid on top of the Foil-Tec Single, spaced at centres to suit the particular flooring.

The decking is then fixed with screws (at 200mm centres) into battens/joists providing 25mm penetration into the 50mm wide battens/joists


Aluminium Foil Insulation for Suspended Timber Floor Applications

Foil-Tec Double can be used with Floorboards or Tongue & Groove floor paneling

Foil-Tec Double is a multi-layer foil laminate, coated with polyethylene to provide a corrosion resistant insulation system.

Foil-Tec Double is a high-performance material which acts creating a low emissivity air space below the floor, thus reflecting the heat back.

Foil-Tec Double can be applied to enhance ‘U’ values in new build or
refurbished building projects to meet and exceed current Building Regulations.


Suspeded Timber Floor Applications

Reflecting the heat back, Foil-tec Double is a high-performance material when combined with a low emissivity air space below the floor

Foil-Tec Single is rolled out with the shiny side facing upwards, over the joists

Foil-Tec Single is then nailed in place through the Foil-Tec Saddle Clips to main tain required air gap - 4 per m 2

The horizontal joints are overlapped by 100mm and are left open to allow any moisture accumulation to dissipate
Foil-Tec SIngle must be brought up (behind the skirting board) to 75mm

The decking is then fixed with screws (at 200mm centres) 37mm into the joists

Installation

Foil-Tec Double is rolled out over the joists

Foil-Tec Double is then nailed in place through the Foil-Tec Saddle Clips to maintain required air gap - 4 per m²

The horizontal joints are overlapped by 100mm and are left open to allow any moisture accumulation to dissipate

Foil-Tec Double must be brought up (behind the skirting board) to 75mm

The decking is then fixed with screws (at 200mm centres) 37mm into the joists

Joist End Fitting Recommendations

Make 2 x 75-100mm cuts in Foil-tec - same width as joist. Then make one further cut, same width again, on each side. Fold up flap(A), fold back flaps (B) and pull Foil-tec (C) up to meet wall. Fix to wall and fit skirting board over, concealing Foil-tec.

 

Foil-Tec — Technical Specifications

Fire Properties

Foil face meets Class 1

Thermal Resistance of 50mm cavity

1.327 M²K/W

Environmental

CFC & HCFC Free

Dimensions

Thinkness

less than 1mm

 

Width

1m, 1.5m

 

Length

50m roll

Foil-Tec Technical Reference

Building Regulations 2000 Approved Document LI, L2 Building Standards Part J.

BS EN ISO 6946 Thermal Resistance Calculation Downward Heat Flow.

BRE publication -Thermal Insulation: Avoiding the risks.

BS EN ISO 13370 - Heat Transfer via The Ground Calculation Method.


Page last update Tuesday, June 29, 2010