Premium performance rigid phenolic insulation thermal conductivity as low as 0.021 W/m.K
Class 0 / Low Risk fire rating
Negligible smoke obscuration
Suitable for use in rainscreen cladding systems
Clear cavity is maintained resists moisture penetration
Unaffected by air movement
Resistant to the passage of water vapour
Easy to handle and install
Ideal for new build and refurbishment
Non deleterious material
CFC/HCFC free with zero Ozone Depletion Potential (ODP)
Product Description
The Facings
Kingspan Kooltherm® K15 Rainscreen Board is faced on both
sides with a low emissivity composite foil facing which is highly
resistant to the transmission of water vapour.
The Core
The core of Kingspan Kooltherm® K15 Rainscreen Board is a
premium performance CFC/HCFC–free rigid thermoset
phenolic insulant of typical density 35 kg/m3.
CFC/HCFC–free
Kingspan Kooltherm® K15 Rainscreen Board is
manufactured without the use of CFCs/HCFCs and
has zero Ozone Depletion Potential (ODP).
Standard Dimensions 1200mm x 2400mm
Kingspan Kooltherm® K15 is available in the
standard size of 1200mm wide by 2400mm long, and is readily available from us in the following most popular thicknesses ... 40mm, 50mm, 60mm and 70mm.
We can also source the following sizes for larger orders ... 25mm, 30mm, 75mm, 80mm, 90mm, 100mm, 110mm, 120mm, 130mm, and 140mm. However, short lead times may apply.
Compressive Strength
Typically exceeds 100 kPa at 10% compression when tested
to BS EN 826: 1996 (Thermal insulating products for building
applications. Determination of compression behaviour).
Water Vapour Resistance
Modified to include board facings, the boards achieve a
resistance far greater than 100 MN.s/g, when tested in
accordance with BS 4370–2: 1993 (Methods of test for rigid
cellular materials. Methods 7 to 9)
Durability
If correctly applied, Kingspan Kooltherm® K15 Rainscreen has an indefinite life. Its durability depends on the supporting
structure and the conditions of its use.
Resistance to Solvents, Fungi & Rodents
The insulation core is resistant to short–term contact with
petrol and with most dilute acids, alkalis and mineral oils.
However, it is recommended that any spills be cleaned off fully
before the boards are installed. Ensure that safe methods of
cleaning are used, as recommended by the suppliers of the
spilt liquid.
The insulation core is not resistant to some
solvent–based adhesive systems, particularly those containing methyl ethyl ketone. Adhesives containing such solvents should not be used in association with this product.
Damaged boards or boards that have been in contact with harsh solvents or acids should not be used.
Fire Performance
The rigid phenolic insulation core of Kingspan Kooltherm® K15 Rainscreen Board will achieve the results given below, which enable it to be
classified by the Building Regulations as being Class 0 and as
Low Risk by the Technical Standards in Scotland.
The fire rating of Kingspan Kooltherm® K15 boards
when subjected to British Standard fire tests, will vary, depending on the particular application.
Test - BS 476–6: 1989
(Fire tests on building
materials and structures.
Method of test for fire
propagation for products)
Result - Fire propagation index of Fire tests on building performance (1) not exceeding 12 and sub Index (i1) not exceeding 6 (for rigid phenolic insulation core)
Test - BS 476–7: 1997
(Fire tests on building materials
and structures. Method of test
to determine the classification
of the surface spread of flame
of products
Result - Class 1 rating
Test - BS 5111–1: 1974
(Smoke Obscuration)
Result - < 5%
Test BS 8414: 2002 (Fire performance
of external cladding systems.
Test methods for non–load bearing
external cladding systems applied
to the face of a building)
Result - Successfully tested – Kingspan Kooltherm® K15 Rainscreen Board does not contribute to fire propagation / spread within a cladding system
Kingspan Kooltherm® K15 Rainscreen Board meets the
criteria within BR 135 (Fire performance of external thermal
insulation for walls of multi–storey buildings), and is therefore
acceptable for use above 18 metres in accordance with the
Building Regulations / Standards.
Typical Applications
Kingspan Kooltherm® K15 Rainscreen Board is installed
between proprietary fixing brackets. The insulation boards are
easily cut to individual bracket spacings. Once installed,
Kingspan Kooltherm® K15 Rainscreen Board can exceed
Building Regulations / Standards requirements for these
applications.
Cold Bridging
The use of a neoprene / plastic gasket between the
'helping hand' bracket and the structure will help to mitigate
the effects of cold bridging. Please contact the Kingspan
Insulation Technical Service Department (see rear cover) for
further information.
Water Vapour Control - Surface Condensation
Surface condensation can be controlled by the selection of
the correct thickness of insulation, the heating and ventilation
system being designed with condensation in mind, and
subsequently the combination of heating and ventilation being
used correctly.
Water Vapour Control - Interstitial Condensation
The Kingspan Insulation Technical Service Department (see
below) can provide a condensation risk analysis of your
proposed design. Alternatively, the designer can undertake an
independent assessment by following the procedures set out
in BS 5250: 2002 (Code of practice for the control of
condensation in buildings).
The vapour resistance of the internal wall lining can be
increased by the use of a vapour check plasterboard or by the
application of two coats of Gyproc Drywall Sealer, if required.
Fire Stops
Current Building Regulations / Standards should be considered
with regard to the requirements for and provision of fire stops.
Lightning Protection
Building designers should give consideration to the requirements
of BS EN 62305: 2006 (Protection against lightning).
Typical U–values
Because rainscreen systems are proprietary and utilise different
mechanisms for attaching cladding panels to the wall structure,
it is advisable to contact the Kingspan Insulation Technical
Service Department (see rear cover) for specific U–value
calculations. All calculations are performed in accordance with
BR 443 (Conventions for U–value calculations, 2006 Edition).
Installation
Due to rainscreen cladding systems are proprietary and
utilise different mechanisms for attaching cladding panels to
the wall structure, sitework guidance should be sought from
system manufacturers.
However, in the absence of any other guidance Kingspan Kooltherm® K15 Rainscreen Board can be fully restrained
against the structural wall in a brick bond pattern with suitable
insulation fasteners. A minimum number of nine fasteners
should be placed within the individual board area and be
sited > 50 mm but < 150 mm from the edges and corners
of the board. Refer to:
Cutting should be carried out either by using a fine toothed
saw, or by scoring with a sharp knife, snapping the board over
a straight edge and then cutting the facing on the other side.
Ensure accurate trimming to achieve close butting joints and
continuity of insulation.
Weatherproofing
Manufacturers' approved rainscreen cladding tape should be
applied to the external joints of insulation board to provide a
weathertight finish.
Refer to individual manufacturer’s fixing instructions ...
Kingspan Kooltherm K15 Rainscreen Board is faced both sides and is used to insulate behind cladding systems, and should be installed between proprietary fixing rails.
The insulation boards are easily cut to individual rail spacings. Once installed the rainscreen cladding system can exceed Building Regulations.