Benefits:

High performance rigid urethane insulation – thermal conductivity 0.023 W/m.K
On average its use creates 15% more usable warm roof space
Insulation of pipes and tanks is unnecessary
No condensation risk
Unaffected by air movement
Resistant to the passage of water vapour
Easy to handle and install
Ideal for new build and refurbishment
Non–deleterious material
CFC/HCFC–free with zero Ozone Depletion Potential (ODP)

Product Description

The Facings

Kingspan Thermapitch® TP10 is faced on both sides with a low emissivity composite foil facing which is highly resistant to the transmission of water vapour. This reflective, low emissivity surface can effectively double the thermal resistance of the cavity in which the board is placed..

The Core

The core of Kingspan Thermapitch® TP10 is manufactured from trademarked Nilflam® technology (a high performance CFC/HCFC–free polyisocyanurate (PIR) based formulation). Kingspan Thermapitch® TP10 has a typical density of 32 kg/m3.

CFC/HCFC–free

Kingspan Thermapitch® TP10 is manufactured without the use of CFCs/HCFCs and has zero Ozone Depletion Potential (ODP).

Standard Dimensions 1200mm x 2400mm

Kingspan Thermapitch® TP10 is available in the standard size of 1200mm wide by 2400mm long, and in the following thicknesses ... 20mm, 25mm, 30mm, 40mm, 50mm, 55mm, 60mm, 65mm, 70mm, 75mm, 80mm, 90mm, 95mm, 100mm, 105mm, 110mm, 115mm, 120mm, 125mm, 130mm, 135mm, 140mm, 145mm, 150mm, and 155mm.

We supply Kingspan Thermapitch® TP10 in Scotland (due to lack of availability of Celotex) and in certain parts of England where TP10 is stocked. However, we find in many parts of England that we are restricted to providing most Kingspan products in pack quantities only.

Our preference is to supply Celotex boards, as they are generally cheaper, more readily available (outside of Scotland), and more versatile, than their TP10 equivalents. Meanwhile, both boards have identical thermal values.

Compressive Strength

Typically exceeds 140 kPa at 10% compression when tested to BS EN 826: 1996 (Thermal insulating products for building applications. Determination of compression behaviour).

Water Vapour Resistance

Modified to include board facings, the boards achieve a resistance far greater than 100 MN.s/g, when tested in accordance with BS 4370–2: 1993 (Methods of test for rigid cellular materials. Methods 7 to 9)

Where additional vapour control is required an appropriate surface treatment should be applied over the completed insulated wall area (see ‘Water Vapour Control’)

Durability

If correctly applied, the Kingspan Thermapitch® TP10 Board has an indefinite life. Its durability depends on the supporting structure and the conditions of its use.

Resistance to Solvents, Fungi & Rodents

The insulation core is resistant to short–term contact with petrol and with most dilute acids, alkalis and mineral oils.

However, it is recommended that any spills be cleaned off fully before the boards are installed. Ensure that safe methods of cleaning are used, as recommended by the suppliers of the spilt liquid. The insulation core is not resistant to some solvent–based adhesives systems, particularly those containing methyl ethyl ketone. Adhesives containing such solvents should not be used in association with this product.

Damaged boards or boards that have been in contact with harsh solvents or acids should not be used.

Fire Performance

Kingspan Thermapitch® TP10, when subjected to British Standard fire tests, achieves the results given below.

Test - BS 476–3: 1958 (External fire membrane adopted exposure roof test)

Result - SAA rating

Test - BS 476–7: 1997 (Fire tests on building materials and structures. Method of test to determine the classification of the surface spread of flame of products

Result - Class 1 rating

Unventilated (Sealed and Unsealed) and Ventilated Constructions

There is generally a choice between either approach, except in the case of refurbishment / loft conversions. In these instances, unless the whole roof is to be stripped, it is impossible to use an unventilated roof, because a breathable sarking membrane cannot be installed.

Recent research suggests that the unventilated, sealed roof approach yields a more energy efficient roof as the impacts of ventilation and incidental infiltrating cold air are negated.

Position of Insulation

Dependent on the designed insulation value of the construction and the available rafter depth and headroom, different approaches can be taken. It is recommended to use two layers of insulation to achieve required U–values. The major benefit of two layer systems and the Insulation

Over Rafters

Rafter approach is that thermal bridging caused by the rafter is prevented and the potential for pattern staining in the position of the rafters is completely avoided. The choice may be influenced by the available headroom and concerns over the depth of bargeboards.

Approaches with a layer of insulation over rafter are likely to yield very large fascia boards and so generally, between and under rafter insulation approaches are probably more desirable.
Note: However, where the choice is for two layers, the layer with the greatest effective R–value should be placed uppermost in order to prevent condensation between the two layers.

Unventilated Roof – Ventilation Considerations

Unventilated roof approaches create a warm pitched roof space, which does not require cross ventilation. Recent research suggests that sealing an unventilated roof yields a more energy efficient roof, as the impacts of ventilation and incidental infiltrating cold air are negated. Therefore, if creating an unventilated roof, it is preferable to fully seal all joints in the breathable sarking membrane with tape. Any water vapour reaching the breathable sarking membrane escapes without condensing. There is then adequate air movement beneath the tiles to dissipate this water vapour to the outside atmosphere.

Tape for sealing joints in the breathable sarking membrane should be specified in accordance with the recommendations of the breather membrane manufacturer.

The requirement for a vapour control layer and / or under–tile ventilation should be assessed to BS 5250: 2002 (Code of practice for control of condensation in buildings).

Vapour check plasterboard or a separate vapour control layer can be specified as preferred, if required.

Ventilated Roof – Ventilation Considerations

In these cases the Building Regulations / Standards require a 50 mm ventilation air gap between the insulation and the sarking felt, so as to avoid condensation.

The requirement for a vapour control layer should be assessed to BS 5250: 2002 (Code of practice for control of condensation in buildings). Vapour check plasterboard or a separate vapour control layer can be specified as preferred, if required.

Breathable Sarking Membrane

BS 5250: 2002 recommends that the vapour resistance of the breathable sarking membrane must not exceed 0.60 MN.s/g e.g. Kingspan Nilvent®.

Position of Breathable Sarking Membrane

The taping of breathable sarking membrane joints is considerably easier to achieve if the membrane is installed on a continuous surface.

In these cases, the breathable sarking membrane is installed under the counter–battens, which provide a channel for water drainage, or in situations with a sarking board under a slated roof, directly under the slates (as neither tile battens nor counter–battens are used).

Generally, when a continuous surface is available, it will prove easier to install the breathable sarking membrane in horizontal runs, whilst still enabling easy sealing between runs.

In some cases with a continuous surface (Figures 1a & 3a, and 1b & 3b when counter-battens, tiling battens and tiles replace slates nailed directly into the sarking board) the breathable sarking membrane can be installed over the counter–battens.

This yields a marginally better design U–value but it may be more difficult to seal the breathable sarking membrane joints effectively, as the membrane must be draped over the counter–battens in horizontal runs so as to provide a water drainage channel. The air movement allowed by the unsealed membrane may negate the benefit of putting the membrane above the counter–battens.

In situations where there is no continuous surface, the breathable sarking membrane can be draped over the rafters in horizontal runs to provide a channel for water drainage.

In this situation, sealing of the breathable sarking membrane joints will prove difficult.

In roofs with no continuous surface, it is preferable, though more difficult, to install the breathable sarking membrane in vertical runs with junctions between runs sealed by counter–battens placed over the laps in rafter positions.

The breathable sarking membrane is installed taut as the counter–batten provides a space for water drainage.

Recommended Solutions for New Build / Re–roofing

The ideal solution for new build or re–roofing projects is, therefore, between and under rafter insulation with a continuous surface for the breathable sarking membrane so that it can be installed in horizontal runs under counter–battens with laps sealed.

The next best solution is, therefore, between and under rafter insulation with no continuous surface for the breathable sarking membrane, and the breathable sarking membrane installed in vertical runs with laps sealed under counter–battens.

Mansard Roofs / Walls

Kingspan Thermapitch® TP10 can be used for the construction of insulated tiled or slated mansard roofs / walls. Its application on such contracts is identical to the standard specification, which is given here.

Fire Stops

Current Building Regulations / Standards should be considered with regard to the requirements for and provision of fire stops.

Over Rafter Layer of Insulation

Over rafter insulation without a sarking board, is simply fixed by placing the Kingspan Thermapitch® TP10 boards over the rafters and under 38 x 38 mm treated softwood counter–battens in line with the rafters. Secure the counter–battens to the rafters by fixing through both the counter–battens and the Kingspan Thermapitch® TP10.

Over rafter insulation with slates fixed directly into a sarking board, is simply fixed by placing the Kingspan Thermapitch® TP10 boards over the rafters with the sarking board overlaid. Secure the sarking board and Kingspan Thermapitch® TP10 to the rafters by fixing through both the sarking board and the Kingspan Thermapitch® TP10.

Over rafter insulation with a sarking board and tiles on tiling battens and counter–battens, is simply fixed by placing the Kingspan Thermapitch® TP10 boards over the rafters with the sarking board overlaid, and with 38 x 38 mm softwood treated counter–battens in line with the rafters.

Secure the counter–battens to the rafters by fixing through the counter–batten, the sarking board and the Kingspan Thermapitch® TP10.

Kingspan Thermapitch® TP10 should be tightly butted.

Boards may be laid either across or down the line of the rafters and should preferably be laid break bonded. All board joints running from eaves to ridge must occur over rafters. There is no necessity to tape board joints. A preservative treated stop rail should be secured to the rafters close to the eaves.

Fixings for Over Rafter Insulation

Helifix In–Skew, Target Skewfast, Wallfast, Timfix or similar approved fixings should be applied at centres appropriate to the design of the roof and location of the building.

Refer to:

Helifix Limited +44 (0) 20 8735 5222;
Target Fixings Limited +44 (0) 1344 777 189; or
Wallfast Limited +44 (0) 23 9229 8443.

Between Rafter Layer of Insulation

Between rafter insulation can be installed by three methods.

In cases where the insulation between rafters is to be flush with the top of the rafters but does not fill the full rafter depth (Figure 3), install the insulation by the use of nailable sarking clips. The nailable sarking clips are driven into the upper surface of each rafter at one–metre intervals up the roof slope.
The nailable sarking clips then support lengths of Kingspan Thermapitch® TP10 suitably trimmed to size and placed between the rafters.
In cases where the insulation between rafters is to be flush with the bottom of the rafters but does not fill the full rafter depth (Figures 1c, 1d, 2a & 2b), install the insulation with the aid of battens nailed to the side of the rafters. The battens should be in the appropriate position to ensure the insulation is flush with the bottom of the rafters.
In cases where the insulation between rafters fully fills the rafter depth (Figures 1a & 1b), simply install the correct thickness of insulation in such a manner that it is flush with the bottom of the rafters.

In all cases, ensure that insulation boards are tightly butted and that there is a tight fit between the insulation and the rafters. Fill all gaps with expanding urethane sealant.

Under Rafter Layer of Insulation

Please refer to literature for Kingspan Kooltherm® K18 Insulated Dry–lining Board.

Breathable Sarking Membrane

The specified breathable sarking membrane (e.g. Kingspan nilvent®) is applied as specified. Application advice should be sought from the appropriate membrane manufacturer.

Sarking Felt

In cases without a sarking board, the sarking felt is draped over the rafters to provide a channel for water drainage and held in place by the slate / tile battens, which are nailed through the felt to the rafters.

In cases with a sarking board, the sarking felt is applied over the sarking board and held in place by the slates or counter–battens which are nailed through the felt to the sarking board.

Slating and Tiling

Slating and tiling over Kingspan Thermapitch® TP10 is exactly the same as on any other pitched roof except that in some instances the slate / tile battens are fixed to the previously applied counter–battens. It is, however, essential that slate or tiling rubble does not lie in contact with the breathable sarking membrane (if used) as this may allow wind driven rain or melted snow to penetrate the breathable sarking membrane.

Surface Treatment

Kingspan Thermapitch® TP10 has a foil faced durable surface and no further treatment is necessary. Kingspan Thermapitch® TP10 is not intended to provide an internal finish and should be underlined with a suitable building board.

Cutting

Cutting should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side.
Ensure accurate trimming to achieve close–butting joints and continuity of insulation.

Daily Working Practice

Installed Kingspan Thermapitch® TP10 boards should be protected against inclement weather.

Manufacturer's details

Kingspan Insulation Ltd., Pembridge, Leominster, Herefordshire, HR6 9LA

Web site: Kingspan Home Page

Kingspan Technical Advisory Service

While just-insulation provides the very best products at the very best prices ... for the very best advise we recommend you contact Kingspan directly.

General Enquiries - Telephone: 0870 850 8555 - Fax: 0870 850 8666
Email: info.uk@insulation.kingspan.com
Technical Advice - Telephone: 0870 850 8333 - Fax: 01544 387 278
Email: techline.uk@insulation.kingspan.com
Tapered Roofing Enquiries - Telephone: 0870 761 7770 - Fax: 01544 387 289
Email: tapered.uk@insulation.kingspan.com
Literature and Samples - Telephone: 0870 733 8333 - Fax: 01544 387 299
Email: literature.uk@insulation.kingspan.com
Kingspan Online SAP Estimator - Specifiers click Here
Page last updated Tuesday, June 1, 2010
 

Order via Internet by 10am for next working day delivery

Telephone orders will require two working days delivery

View the list of all items

sold through our eShop

Kingspan Thermapitch® TP10 Insulation Boards
PUR boards between & over rafter applications

» View complete list

Product Categories ...

Bubble Foil Insulation

Insulation Polystyrene

Drywall Partitioning

Acoustic Insulation

Tapes and Cladding

Elastomeric Insulation

Fire Protection

Insulation by Brand ...

Jablite / Jabfloor

Speedline

Additional Information ...

 

www.just-insulation.com

27 Massetts Road

Horley, RH6 7DQ, U.K.

 

Tel: 0845 260 6232

Fax: 0845 260 6242

Email: Click Here

 

VAT Reg: 753 5101 13

Company Reg: 4597028

The Kingspan Thermapitch TP 10 Range is a rafter level insulation for tiled or slated pitched warm roof spaces, constructed with high performance rigid urethane. Kingspan Thermapitch TP10 is faced on both sides with a low emissivity composite foil facing which is highly resistant to the transmission of water vapour. These reflective low-emissivity surfaces can effectively double the thermal resistance of the cavity in which the board is placed. The core of Kingspan Thermapitch TP10 is manufactured from a high performance CFC/HCFC–free polyisocyanurate (PIR) based formula

Kingspan TP10 (PIR)

The Kingspan Thermapitch TP10 Range are performance rigid urethane boards used for rafter level insulation for tiled or slated pitched warm roof spaces.

These boards are faced on both sides with a low emissivity composite foil facing that is highly resistant to the transmission of water vapour

.