TLX Silver, previously Thinsulex Silver

Complies with Part L by combining the benefits of thin foil insulation with other insulation materials. Using Thinsulex Silver as a platform it is possible to build the required U-value using the BRE U-value calculator. This provides a wide range of options which can be influenced by rafter thickness and width as well as whether rafters are partially or completely exposed.

100mm Rafter 0.2 U-Value Examples

TLX Silver below rafters with Celotex 60mm between rafters and breather membrane above

TLX Silver below rafters with Celotex 70mm

 

TLX Silver below rafters with 110mm mineral glass wool between rafters and breather membrane

TLX Silver 100mm rafter solution incorporating 120mm mineral glass wool

 

TLX Silver below 100 rafters with 70mm Celotex between rafters and iF Felt above

TLX Silver 100mm rafters under 1F Felt with 80mm Celotex

 

150mm Rafter 0.2 U-Value Examples

TLX Silver below rafters with Celotex 70mm between 150mm rafters and breather membrane
TLX Silver above rafters with Celotex 70mm between rafters and 1F felt

 

TLX Silver above rafters with Celotex 60mm between rafters and breather membrane on top

TLX Silver above rafters with Glasswool 120mm between rafters and breather membrane

TLX Silver below rafters with 105mm mineral glass wool between rafters and breather membrane

TLX Silver below rafters with Celotex 70mm between 150mm rafters and 1F roofing felt

N.B. Glasswool at 105mm with a 0.032 W/mK Lamba value may not be readily available, but is shown as the minimum requirement

 

TLX Silver above rafters with Glasswool 105mm between rafters and breather membrane.
TLX Silver below rafters with Glasswool 120mm between rafters and breather membrane

N.B. Glasswool at 105mm with a 0.032 W/mK Lamba value may not be readily available, but is shown as the minimum requirement.

Timber frame 90mm stud wall 0.3 solutions

TLX IN Loft conversion solutions – dormer cheek

Loft conversion solutions –

TLX with Semi-exposed rafter + 80mm foiled rigid insulation

Fully-exposed rafter + 50mm foiled rigid insulation

General installation guidelines for Thinsulex

Thinsulex can be attached to the rafters by using double sided tape, glue, staples or nails.
Thinsulex Silver should have a 50mm overlap and be taped along the entire length of the joint with a self-adhesive aluminium foil tape.

For under rafter applications

Starting at the ridge and working down, unroll Thinsulex Silver parallel to the eaves.
Cross batten Thinsulex Silver from the ridge downwards with the batten spacing no greater than 600mm. The cross battens should be a minimum of 25mm thick.
Finally fix the internal foil backed plasterboard to the cross battens.

For over rafter applications

Starting at the eaves and working upwards, unroll Thinsulex Silver parallel to the eaves.
Fix battens on top and along the line of the rafters.
Install breather membrane over the battens.
Fix the membrane in place with the tile battens.
iles/slates should be fitted as soon as possible.
When installing additional insulation

PIR/PUR such as Celotex or Kingspan

Install the PUR (with a lambda value of 0.023W/mK) in accordance with manufacturers"™ instructions for an unventilated pitched roof, based on a between rafter application.
Retain a 25mm air gap above and below the PUR.
Mineral wool
Place the 100mm thick mineral wool/fibre glass (with a lambda value of 0.044W/mK) in between the rafters and directly on top of the Thinsulex Silver.

Performance considerations:

As Thinsulex Silver performs as a vapour barrier, it is advisable to utilise a breather membrane, preferably reflective, in your roof system. This will eliminate the need for additional ventilation.
When installing PUR to attain the U-value of 0.16W/m2K a minimum rafter depth of 150mm is required.

When using insulated plasterboard, a vapour barrier must be installed.

tlx silver u-value overview

Manufacturer's Details

Contact the manufacturers thermal hotline 01204 674 730 for technical advice
Web Dynamics Ltd Moss Lane, Blackrod, Bolton, Lancashire BL6 5JB

 

Page updated November 10, 2008


Order via Internet by 10am for next working day delivery

Telephone orders will require two working days

View the list of all items

sold through our eShop

TLX Silver Multi Foil ... U-value Calculations

Typical installations backed with a BBA Certificate

» View complete list

Web Site Navigation

 

Insulation by Brand

 

Site Navigation

 


typical 0.20 uvalue TLX under rafter

TLX Silver™ U-values

When installing you can achieve 0.2 U-value with TLX Silver in 100mm rafters by replacing PUR/PIR cross-rafter installation with an additional, second layer of TLX Silver.

Only 80mm of Celotex Tuff-R or Kingspan TP10 is needed if 1F roofing felt is in place. And, only 70mm if a breather membrane is installed.